p5qgw7rzxlvvfpzc0etd.png
Project

Wave 3

The council received a grant from SHF Warm Homes to deliver retrofit of 400 council homes.

Haringey Retrofit Consultations

Wave 3 Retrofit and Decency Works Programme (2025–2028)

Haringey Council has secured funding through the Warm Homes: Social Housing Fund (Wave 3) to deliver energy efficiency and decency upgrades to approximately 403 council homes across the borough between 2025 and 2028.

Programme Overview

This project aims to improve the energy performance of Haringey’s social housing stock while ensuring homes meet modern standards of decency. The works will include a combination of energy efficiency measures (EEMs) and component upgrades, tailored to the needs of each property.

Location

The 403 homes included in this programme are distributed across Haringey and align with the four contract areas defined in the Council’s Partnering Framework:

  • West
  • Central
  • East North
  • East South

Energy Efficiency Measures

The energy efficiency measures proposed in the Wave 3 bid were indicative and based on modelling using Parity Projects’ software, without prior on-site validation.

Haringey’s retrofit strategy follows the PAS 2035 framework, prioritising:

  1. Fabric-first improvements
  2. Low-carbon heating solutions
  3. Renewable energy technologies

However, not all properties will be suitable for measures such as external wall insulation (EWI) or internal wall insulation (IWI) due to factors like:

  • Conservation area restrictions
  • Complex building facades
  • Limited internal space
  • Other structural or planning constraints

Final decisions on the scope of works will be made following detailed on-site assessments and design development for each property.

Property Archetypes

Haringey’s social housing stock has been categorised into 22 archetypes based on previous analysis. This programme will focus on seven key archetypes, selected for their suitability for retrofit and potential for energy performance improvement.

The final selection of measures will be determined following on-site retrofit assessments and design development. Below are possible indicative measures for each archetype:

Single House, Traditional <1900

  • EWI (maximum 10% of archetype)
  • IWI (to be explored)
  • New draughtproof windows and doors
  • Loft Insulation
  • High heat retention storage heaters and dual immersion cylinder from electric heating
  • Low energy lighting
  • Full Multi Zone Controls
  • Ventilation

Single House, Traditional >1899

  • EWI (maximum 10% of archetype)
  • IWI (to be explored) 
  • New draughtproof windows and doors
  • Loft Insulation
  • High heat retention storage heaters and dual immersion cylinder from electric heating
  • Low energy lighting
  • Full Multi Zone Controls
  • Ventilation

Single House, Heritage

  • IWI (to be explored)
  • New draughtproof windows and doors (to be explored)
  • Floor insulation
  • Loft Insulation
  • High heat retention storage heaters and dual immersion cylinder from electric heating
  • Low energy lighting
  • Full Multi Zone Controls
  • Ventilation

Single House, Conventional

  • EWI
  • CWI
  • IWI
  • New draughtproof windows and doors
  • Floor insulation
  • Loft Insulation
  • High heat retention storage heaters and dual immersion cylinder from electric heating
  • Low energy lighting
  • Full Multi Zone Controls
  • Ventilation

Bungalow

  • EWI
  • CWI
  • IWI
  • New draughtproof windows and doors
  • Floor insulation
  • Loft Insulation
  • High heat retention storage heaters and dual immersion cylinder from electric heating
  • Low energy lighting
  • Full Multi Zone Controls
  • Ventilation 

          Crosswall House

  • EWI (to be explored)
  • IWI (to be explored)
  • New draughtproof windows and doors
  • Floor insulation
  • Loft Insulation
  • High heat retention storage heaters and dual immersion cylinder from electric heating
  • Low energy lighting
  • Full Multi Zone Controls
  • Ventilation

Timber Frame House

  • EWI (to be explored)
  • IWI (to be explored)
  • New draughtproof windows and doors
  • Floor insulation
  • Loft Insulation
  • High heat retention storage heaters and dual immersion cylinder from electric heating
  • Low energy lighting
  • Full Multi Zone Controls
  • Ventilation

SHF retrofit Wave 3 latest news

Retrofit assessments are currently ongoing for Wave 3 with just over 250 retrofit assessments completed.

Retrofit designs for eligible properties are being worked up.

Stay Informed

Follow our projects to get notified of upcoming engagements and the latest project related news.